Your Vehicle: 2009 Nissan-Datsun Altima V6-3.5L (VQ35DE)
 
Vehicle » Heating and Air Conditioning » Description and Operation » Refrigeration System » Refrigerant Cycle  
 
 
  Refrigerant Cycle  
 

REFRIGERATION SYSTEM

Refrigerant Cycle

Refrigerant flow
The refrigerant flows in the standard pattern, that is, through the compressor, the condenser with liquid tank, through the evaporator, and back to the compressor. The refrigerant evaporation through the evaporator coil is controlled by an externally equalized expansion valve, located inside the evaporator case.