Your Vehicle: 2009 Nissan-Datsun Altima V6-3.5L (VQ35DE)
 
Vehicle » Powertrain Management » Computers and Control Systems » Information Bus » Testing and Inspection » Component Tests and General Diagnostics » CAN Communication Circuit » CAN System (Type 4)  
 
 
  CAN System (Type 4)  
 

CAN COMMUNICATION CIRCUIT

Diagnosis Procedure

Inspection PROCEDURE
1.CONNECTOR Inspection

  1. Turn the ignition switch OFF.
  2. Disconnect the battery cable from the negative terminal.
  3. Disconnect all the unit connectors on CAN communication system.
  4. Check terminals and connectors for damage, bend and loose connection. Is the Inspection result normal?

YES >> GO TO 2.
NO >> Repair the terminal and connector.
2.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector terminals.

  

Is the Inspection result normal?
YES >> GO TO 3.
NO >> Check the harness and repair the root cause.
3.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the data link connector and the ground.

  

Is the Inspection result normal?
YES >> GO TO 4.
NO >> Check the harness and repair the root cause.
4.CHECK ECM AND IPDM E/R TERMINATION CIRCUIT

  1. Remove the ECM and the IPDM E/R.

  

  1. Check the resistance between the ECM terminals.

  

  1. Check the resistance between the IPDM E/R terminals.

  

Is the measurement value within the specification?
YES >> GO TO 5.
NO >> Replace the ECM and/or the IPDM E/R.
5.CHECK SYMPTOM
Connect all the connectors. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.
Inspection result
Reproduced>>GO TO 6.
Non-reproduced>>Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.
6.CHECK UNIT REPRODUCTION
Perform the reproduction test as per the following procedure for each unit.

  1. Turn the ignition switch OFF.
  2. Disconnect the battery cable from the negative terminal.
  3. Disconnect one of the unit connectors of CAN communication system.

NOTE:
ECM and IPDM E/R have a termination circuit. Check other units first.

  1. Connect the battery cable to the negative terminal. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced.

NOTE:
Although unit-related error symptoms occur, do not confuse them with other symptoms.
Inspection result
Reproduced>>Connect the connector. Check other units as per the above procedure.
Non-reproduced>>Replace the unit whose connector was disconnected.