TRUNK LID OPENER ACTUATOR
Description
Performs trunk lid open with signal from BCM.
TRUNK LID OPENER ACTUATOR
Diagnosis Procedure
1.CHECK OUTPUT CIRCUIT
- Turn ignition switch OFF.
- Disconnect trunk lamp switch and trunk release solenoid connector.
- Check voltage between trunk lamp switch and trunk release solenoid connector and ground.
Is the Inspection result normal?
YES >> GO TO 4
NO >> GO TO 2
2.CHECK OUTPUT SIGNAL
Check voltage between BCM connector and ground.
Is the Inspection result normal?
YES >> Repair or replace harness.
NO >> GO TO 3
3.CHECK TRUNK LID OPENER ACTUATOR CIRCUIT
- Disconnect BCM.
- Check continuity between BCM connector and trunk lamp switch and trunk release solenoid connector.
- Check continuity between BCM connector and ground.
Is the Inspection result normal?
YES >> Replace BCM. Refer to See: Body and Frame\Body Control Systems\Body Control Module\Service and Repair.
NO >> Repair or replace harness.
4.CHECK TRUNK LID OPENER GROUND CIRCUIT
Check continuity between trunk lamp switch and trunk release solenoid connector and ground.
Is the Inspection result normal?
YES >> Replace trunk lamp switch and trunk release solenoid.
NO >> Repair or replace harness.
|